The CARDIOLOGIC EXPLORER (CAE)

The CARDIOLOGIC EXPLORER (CAE) offers a broad, non-invasive and fast diagnosis of the heart potential. In addition to well-known and established procedures, the device also utilizes the methodology of the Cardiogoniometry.

The fast and stress-free detection of myocardial ischemia (in most cases due to coronary stenosis or small vessel disease) offers a valid diagnosis for patients suffering from:

  1. dropdown_cardio_teaserAcute coronary syndrome even without ST-elevation (NSTE-ACS)
  2. Acute as well as non-specific chest pain
  3. Non diagnostic ECG and negative troponin

The following modules are available:

  • Cardiogoniometry
  • 12C Rest ECG, including automatic measuring and diagnosis (HES-algorithm)
  • Ergometry
  • CHEST PAIN EXPLORER for easy diagnosis of acute-patients

Our module system for the CARDIOLOGIC EXPLORER is customized to individual requirements. Modules can be combined with each other.

The following combinations are available:

Cardio­goniometry

The application of vectorcardiography in cardiologic diagnosis has been complicated and complex, therefore it was used only by a few specialists. The CARDIOLOGIC EXPLORER has extended this diagnostic method considerably. It now offers a fast and easy method to identify ischemia completely stress-free and non-invasive, in just seconds.

Automatic Interpretation and Parameters

All software modules incorporate an automatic analysis and provide the user with a suggested diagnosis. In addition to the automatic interpretation option, the user can perform a manual diagnosis based on the various images and save this within the software.

CAE-path-Finding-en
Pathological: Parameters located in the red zone, are most probably a sign of ischemia.

Range of Service

Technical Data

  • ECG and Cardiogoniometry: resolution 22bit, sampling frequency 1116 Hz, 12 channels
  • PC-Interface: USB 2.0
  • Pacemaker: Display and analysis of pacemaker activities
  • Size: 200 x 150 x 55 mm (l/w/h)
  • Weight: 800g
  • Hardware-classification: IIa after attachment IX of 2007/47/EG, L 10
  • Software-classification: 2, IEC 62304

System Requirements (Minimal)

  • CPU: Intel I3
  • RAM: 3 GB
  • Graphic: Intel HD
  • Display: 15 inch at 1024×768 Pixel resolution
  • Interfaces: 2 x USB 2.0
  • Operating System: Windows XP

Standard Range of Service

The standard range of service varies according to the software modules chosen.

  • Device CARDIOLOGIC EXPLORER
  • Installation CD and license-dongle with licenses for the chosen software module(s)
  • USB Cable

12C Rest-ECG:

  • 10-pin patient cable (banana plug)
  • ECG adhesive electrodes (50 pieces banana plug)

Cardiogoniometry:

  • 5-pin patient cable (button plug)
  • CGM adhesive electrodes (50 pieces button plug)
  • CGM ruler

PDF-Download-Button