Model: E30
Portable: ENT Endoscopes
Model: E30
Application: ENT
Clinical Applicaton:
1. Endotracheal/endobronchial examination and intubation
2. Video nasotracheal intubation
3. Double-lumen tube intubation, positioning and position examining
4. Video tracheal secretion suction
5. Video laryngopharynx topical anesthesia
6. Infant intubation (E30)
Product Features:
1. Picture taking and video recording (E30/E41)
2. Insertion tube outer diameter is 3.2 mm and working length is 600 mm.
3. Non-fiberscope, tenacious, flexible, durable, with long service life
4. 3.5″ LCD screen, with vertical adjusting angle (pitching angle) 0°~120°, allowing operators to adjust the angle to meet their needs of observation or according to other practical needs on site.
5. LCD screen is with level adjusting angle -45°~45°, allowing watching from different angles or directions.
6. Nasotracheal intubation or orotracheal intubation of ET tube ID >4.0 mm, positioning of DL tube 33\35\37\39
Model |
E30 |
Distal End OD (mm) |
3.2 |
Working Channel ID (mm) |
—– |
Angulation Range (U/D) |
130º/130º |
Working Length (mm) |
365 |
Depth of Field (mm) |
3-50 |
Field Angle |
90º |
Video Output |
Yes |
Portable LCD Screen |
3.5″ TFT |
Resolution (Pixel) |
High Resolution |
MDH video mobilescope for airway management
Applications of MDH mobile airwayscope
Pre-operation of MDH mobile airwayscope
Operation of MDH Rigid mobile airwayscope
Operation of MDH flexible mobile airwayscope
A10/3.8
Its insertion tube outer diameter is 3.8 mm. It fits ET tube with inner diameter above 4.5 mm or DL tube above 35F. It is applied mainly in intubation for adults and infants, DL tube position examining and cuff positioning.
A10/5.2
Its insertion tube outer diameter is 5.2 mm. It fits ET tube with inner diameter above 6.0 mm. It is mainly applied in adult difficult airway intubation.
A11/5.5
Its insertion tube outer diameter is 5.5 mm. It fits ET tube with inner diameter above 6.0 mm. It is mainly applied in difficult airway intubation for adults. Its working channel inner diameter is 1.4 mm, which is mainly for tracheal secretion suction and drug injection.
A11/6.2
Its insertion tube outer diameter is 6.2 mm. It fits endotracheal tube with inner diameter above 7.0 mm. It is mainly applied in difficult airway intubation for adults. Its working channel inner diameter is 2.0 mm, which is advantageous for tracheal secretion suction
A30
Its insertion tube outer diameter is 3.3 mm. It is capable of tracheal intubation for infants and insertion & positioning of DL tube and bronchial stopper (cuff).
A41